This guide owns operator sign-in and stored-session recovery. Architecture and vendor routing belong to ADR-001.
Hosted Blink sign-in
Use a desktop browser for this callback-copy flow. On a mobile device with the Blink app installed, the registered App Link may open the app instead of leaving a copyable callback in the address bar; no mobile fallback is verified here.
- Open this plugin's settings in the remote Homebridge UI and choose Sign in securely with Blink. Keep the Homebridge settings tab open. If your browser blocks the new tab, choose the revealed Open Blink Sign-In fallback.
- Finish the account-credential and MFA steps only in the separate Blink-hosted browser tab. Homebridge never receives either value.
- After Blink reaches its desktop Unsupported Browser page, copy the full
address beginning with
https://applinks.blink.com/signin/callbackfrom your browser’s address bar. - Return to Homebridge and choose Paste Blink Result and Finish. This reads the clipboard only from that click. If the browser denies clipboard access, reveal the manual field, paste the complete address, and choose Finish with Pasted Address. Clipboard cleanup after completion is best effort: if the browser denies clipboard write access, clear the copied callback address manually.
- If Blink asks for client or account verification after issuing tokens, enter that distinct post-token code in Homebridge. This is not Blink's hosted MFA.
- Wait for stored-token connection verification, then continue to the normal plugin schema. Restart Homebridge and confirm the stored session reconnects.
For PKCE, callback validation, owner-only token storage, OAuth routing and validation boundaries, see ADR-001.
Hosted MFA
Blink's sign-in page owns the account credential and hosted MFA steps. Do not put either value in Homebridge configuration.
Client verification (new device approval)
After tokens exist, Blink may require one-time client verification for the new Homebridge device. The custom UI identifies this post-token requirement, accepts the code through its verification form, and never saves it in plugin configuration. Leave Trust this device enabled unless you intentionally want Blink to ask again.
Account or phone verification
Some accounts require an additional account or phone verification after token issuance. Complete it only when the custom UI labels the request as account verification. If Blink asks for another PIN, request a new one and use the same form; the token state remains authenticated while verification is pending.
Re-authentication and token reset
If you need to re-authenticate or switch Blink accounts, choose Unlock &
Re-authenticate in the custom UI, then start hosted sign-in again. Unlocking
clears the current token file, legacy auth state, and any pending transaction
before returning to the signed-out screen. The custom-UI server's /logout
route has the same local storage-clearing semantics for integrations, but the
current operator UI does not expose a separate logout button. Neither action
revokes tokens at Blink; it removes the plugin's local ability to reuse them.
Sign-in verification checklist
- Open Homebridge UI → Plugins → this plugin → Settings.
- Confirm there is one hosted flow and no Homebridge username, password, or hosted-MFA input.
- Confirm the browser reaches the exact HTTPS App-Link and the clipboard/manual finish returns to an authenticated status.
- Confirm the saved plugin config contains no credentials or verification codes.
- Restart Homebridge and confirm
.blink-auth.jsonsupplies the same account; refresh uses its persisted OAuth profile.
Validation boundary
ADR-001 records the bounded live evidence and incomplete fresh packaged authorization-code acceptance. Non-EU accounts have static/routing-test coverage, not live-account acceptance. Current delivery and security dispositions belong to the hardening ledger.
Stored-session recovery and legacy configuration
Stored JSON is validated before use; supported OAuth profiles are android and
ios. A stored token is not proof that Blink still accepts it: Test Connection
performs that check. Temporary refresh outages retain the current token and advise
retrying; a confirmed rejected refresh grant requires sign-in again.
Credential writes use a short cross-process lock and compare the saved session
before replacing it. Logout also updates .blink-auth.json.generation.json, so
an older child bridge cannot recreate cleared credentials or overwrite a new
account. Restart the child bridge after changing accounts. Requests already sent
and established streams can finish; logout does not revoke tokens at Blink.
New authenticated sign-in can replace damaged JSON after preserving its exact
contents in an owner-only .invalid-<id>.json backup (encoded as a JSON string).
Treat those backups as credentials. If a crash leaves .blink-auth.json.lock
behind, storage fails closed after five seconds. Stop the child bridge and the
custom-UI process, confirm neither is running, remove only that empty lock
directory, then restart. Do not remove the generation file during routine reset.
For compatibility with older installations, the runtime still accepts a
paired username and password in manually edited configuration and can use
them for the legacy iOS-profile sign-in path when compatible token state is
missing or unusable. That hidden fallback sends the credentials through
Homebridge and is deprecated; it is not part of the supported custom-UI flow.
Remove those fields after migrating to hosted sign-in.