Start with the checks below. For safe collection/redaction use the diagnostic specification and the trusted evidence reporter. Never attach token files, raw provider bodies, callback addresses or media to an issue.
Blink connection failure in HomeKit
If startup authentication or device discovery fails, cached Blink accessories remain in HomeKit so rooms, names, and automations are preserved, but their services report a fault instead of appearing healthy.
The stable Blink Connection contact sensor reports confirmed outages after three failed polling cycles. Its monitor remains active while the child bridge runs; an open contact and fault describe unavailable Blink connectivity. A separate Retry Blink Connection switch triggers recovery using stored sign-in state. Repeated requests join the same recovery attempt. Both accessories retain their identities after recovery; no re-pairing is needed.
To receive Apple's supported connection alerts, open Home Settings, choose the sensor accessory type, select Blink Connection, and enable Activity Notifications on each Apple device. Remote alerts require a home hub. Apple Home controls notification presentation: this plugin cannot add a custom Retry/Cancel dialog. Dismiss an alert to leave automatic recovery running; use the Retry switch to request an immediate check. Physical notification delivery must be verified on your devices; a Homebridge log entry is not proof of delivery. See Apple's notification instructions.
HomeKit writes and fresh snapshot responses have a 12-second response limit. Started Blink commands may finish later; a timeout does not replay a mutation. Queued mutations that expire before starting are not sent. Thumbnail captures share durable ownership with mutations and storage work until command completion, while reads and image downloads remain independent. Ordinary controls can reconcile an explicit conflict against confirmed state within their bounds. Native-storage refusals defer locally; an unknown accepted outcome remains owned and does not authorize a replacement preparation. When Blink has already confirmed command completion, a failed media transfer is settled locally so later controls and recording jobs can proceed. Startup and explicit connection retry reconcile known ordinary and native command IDs within their existing bounds. Ordinary polling adds no ownership probes, and unknown IDs remain fenced.
If Blink acknowledged closing an owned Live View but its status check was interrupted, startup or an explicit connection retry checks that known command's status within the existing bound. Recovery does not resend the close request. Unknown command IDs and unacknowledged closes retain their ownership fences. An explicit Retry Blink Connection also reopens a faulted motion receiver using its saved identity and acknowledgments. Ordinary polling keeps its current subscription.
Startup also retires verified downloaded clips and private generated media
remnants left by interrupted downloads before accounting for cache capacity.
It preserves remote operation receipts, unexpected files and .DS_Store.
Do not clear the private state directory to recover from a pending operation.
Persistent snapshots remain manual-refresh images. Their download/cache age and last observed successful capture age are separate diagnostics. A busy capture may return an existing thumbnail and is explicitly labelled as a fallback. Automatic status recovery retries one transient homescreen GET failure within a 25-second budget, without automatically signing in again for network outages. Confirmed outages log a bounded, unauthenticated DNS/connection diagnostic; credentials, response bodies, and resolved IP addresses are excluded.
Motion arrives but no Home recording appears
First complete the recording setup checklist for the affected camera. In Home, open the camera's Recording Options and check that the active When Home or When Away mode is set to Stream & Allow Recording. If the camera recorded before you set a specific motion filter or Activity Zone, switch to Any Motion and test a fresh event. Check Status and Notifications separately if saved clips play but alerts are missing.
Compare one fresh event across the Blink app's playable Local Storage clip, the plugin logs and that camera's saved Home timeline. Record timestamps and camera names without publishing media or private identifiers. A completed Blink clip must exist before this plugin can offer it to Home.
motion-suppressed-home-policy-inactivemeans the camera's effective Home recording policy is unavailable or inactive. Check its Home recording mode, camera availability and connected home hub; the message alone does not identify which setting or readiness condition blocked it.- In
2.0.1-alpha.0, whencatalog-no-eligible-clipaccompaniesacquisition-missing, the newly fetched catalog yielded no eligible row.catalog-rows=0means the response was empty. Otherwise, each row contributes to its first exclusion count for network, camera name, metadata, event time, or prior consumption. This message uses the same temporary flow label as the surrounding events and omits the camera label and catalog values. An empty response alone cannot establish whether Blink recorded the event. - Compare the clip timestamp with the motion event before changing
matchToleranceSeconds. The default 15-second bound excludes candidates farther from the event. Verify several isolated events and adjacent recordings before choosing the smallest measured tolerance, and check all enabled cameras. Changing the initial lookup delay leaves timestamp matching unchanged. - A Home recording request can be rejected while no prepared clip exists. Check acquisition and preparation first; that rejection alone does not establish an encoder or Home transport failure.
The clip appears under its original camera, not a replay camera. Wait for Blink
to finish recording, then for download and local preparation. The default ordinary
lookup starts after 60 seconds; catalog cooldown and queue contention can add
delay. Home may place the entry at delivery time. motionTimeout only controls
the public motion indication; it does not set the saved clip length.
Preparation first repairs recoverable timing; a classified media fault receives
one salvage pass within the original overall deadline. Normal logs identify
recovery=audio-clock, audio-silence or fragments when those actions
were actually used. Silence is a warning that the real video survived with degraded
audio. A terminal recovery=exhausted means the salvage attempt also failed; it is
not a reason to keep a failed recording permanently on the Pi. No backup/archive
mode or indefinite retry queue exists.
Preparation failures use fixed phase and error codes. deadline=exceeded with
phase=admission means the job ran out of time waiting for a local conversion
slot. The other phases identify FFmpeg setup, input inspection, conversion
output, result validation, or private file cleanup and handoff. Preserve the
phase, error code if present, plugin version and event time when reporting a
failure. Acquisition expiry alone leaves the cause open.
Successful download, preparation or a Home transport acknowledgment still needs confirmation by playing the saved clip in Home. Apple's hub decides whether to retain it under your recording policy. See Apple's recording controls.
Live video fails, stutters or stops
First distinguish a current camera problem from a HomeKit conversion problem. Check battery/power status, camera connectivity and live view in the official Blink app with the Home viewer closed. A cached image or the Home “Live” label alone is not proof of changing video or audible audio. Battery depletion and provider outages need separate evidence; a disconnect message alone does not identify their cause.
Check the external FFmpeg installation, service PATH or configured ffmpegPath,
and negotiated codec in bounded startup receipts. Install FFmpeg 6.1+ with the
required capabilities if the setup check reports it missing or incomplete.
The separate packaged protection helper still requires verified package bytes;
an external FFmpeg path cannot replace a missing or modified protection helper.
See media requirements
and the upgrade migration. AAC-ELD is no longer
offered; Home receives the supported codec update through normal HAP metadata.
Do not reset pairing or disable certificate verification to bypass a refused stream.
For stutter, compare the same camera and scene with the same network conditions. The quality guide describes lower output profiles and the optional low-CPU preset. Change one setting at a time, save it, apply it through your normal restart workflow, and verify the effective output receipt. Collect matched CPU/memory and encoder progress before assigning a cause to transcoding or Wi-Fi. Audio has its own negotiation and conversion; changing video quality does not establish audio compatibility.
For STOP/reopen failures, retain timestamps for the explicit close, retirement response or timeout, new stream start, first media and final cleanup. Bounded reconnect exhaustion is a failure receipt, not proof of successful recovery. HTTP 406 may be transient provider behavior; an eligible command GET has one bounded retry, while liveview/completion POSTs are not ambiguously replayed. Never include their capability URLs, command identifiers, process arguments or media in an issue. Use the diagnostic policy and release acceptance guidance to record proof and limitations.
Manual snapshot refresh
Enable the optional manual control through
persistSnapshotCache. In Home,
select the camera's Refresh Snapshot control, not its Motion Detection or
network Security control. The refresh switch returns to Off after the attempt,
including an error; this is a momentary request, not a persistent mode.
A fresh-capture receipt and downloaded-image receipt distinguish a new snapshot from a cached or provider-busy fallback. To verify freshness, close live viewers and retry when the camera is idle. Concurrent requests coalesce, and failed attempts have a 15-second retry backoff. Repeated rapid toggles do not guarantee new images and can consume camera battery. Do not share the image itself in public diagnostic reports.
401 Unauthorized / 403 Forbidden
- Keep
deviceIdstable and use Test Connection to retry with stored tokens. - Change
deviceIdonly when intentionally registering a new client; first use Unlock & Re-authenticate, then complete hosted sign-in and any verification again. - Complete any client/account verification shown by the custom UI.
- If refresh has expired, use Unlock & Re-authenticate and start a fresh hosted sign-in.
- Do not manually choose a geographic tier;
tier_infois authoritative.
Rate Limits (429)
Eligible reads back off within their retry budget. Recording commands do not replay an ambiguous POST. If rate limits recur:
- Increase
pollIntervalto reduce API calls - Check whether a known remote operation is unresolved before retrying a control
- Hide unwanted motion sensors with
exposeMotionDetected; if HSV remains selected, its push subscription stays active without idle storage requests
Node.js Version
The declared Node.js ranges are 20.3+, 22, 24 or 26; see package.json. The push
receiver uses AbortSignal.any, which is unavailable in Node 20.0–20.2.
Check your version:
node --version
Configuration migration required
For stable 0.10.0, follow the combined one-time upgrade.
It handles retired media options and motion settings in one guarded replacement.
Early Notification and legacy HSV mappings apply separately to intermediate beta
users. Both migration script names now default to preview; an explicit --apply
is required to replace the file with a private backup. Do not assume the old
secure-media command still writes when given only a path. Installation does not
run the migration, even with an installer storage path. Windows uses the guide’s manual conversion.
Neither path changes Blink settings or pairing. Existing syncModuleFeedLimits
live-view settings remain valid.
Motion Not Detected
- Ensure global/per-camera
exposeMotionDetectedis enabled for the public sensor - Check that the network is armed (motion events only trigger when armed)
- Check the local push receiver status; reducing
pollIntervaldoes not speed up push - For HSV, check Home camera/recording permissions and whether native Blink Local Storage clips are being saved. A motion alert does not establish a saved clip
- If an accepted command is unresolved, preserve its private state and inspect the known operation. Do not clear ownership or submit a replacement by guess