Documentation Upgrade an existing setup
FIELD GUIDE / 0613 MIN READ

Native recording configuration migration

Documentation home · How it works · Troubleshooting

The redesign uses Blink motion push notifications and completed USB clips. Its configuration exposes motion sensors globally or per camera and enables HomeKit Secure Video separately for each camera. The timing and cache controls are under nativeRecording.

Use the plugin's existing five-section settings editor. Motion exposure belongs to the camera settings; HomeKit recording selects the new per-camera policy. Homebridge Save and a child-bridge restart apply the reviewed configuration.

Installation and one-time conversion

Close all settings and JSON Config editors and stop other configuration writers until explicit migration completes. The final file check and atomic replacement do not form a lock shared with Homebridge's settings service; concurrent writers are outside this migration's supported operating requirements.

Package installation does not modify Homebridge configuration. For legacy settings, run the explicit preview/apply commands below against the complete absolute path to your active config.json before restarting the plugin. An inherited UIX_STORAGE_PATH does not trigger conversion. The converter never infers storage from a package prefix or searches other storage roots. The guarded converter writes an owner-only backup of the exact original bytes before atomic replacement, preserving file ownership and unrelated configuration. Secure-media, motion and recording conversions share this one guarded file operation; do not chain two separate writers. The replacement retains the config permission bits so service group-read access is preserved; the backup stays private at 0600. Already-converted files are left untouched without another backup. Invalid choices, unsafe files and detected concurrent changes fail the migration without replacing the configuration. Review unresolved camera aliases in the explicit preview before applying the migration. Package installation cannot infer aliases; the converter reports issues for review rather than treating installation as configuration approval.

The persisted file contains only canonical values after conversion; the runtime and settings editor do not interpret legacy keys. Opening settings, discovering cameras and testing the connection do not stage or save a configuration change. Only a real edit stages a draft for Homebridge Save. Explicit account operations may save their own changes; unrelated drafts must still be saved or discarded.

Run the explicit preview/apply commands before starting with legacy settings. Missing migration produces an actionable validation error rather than silently choosing a different policy. From a source checkout, run npm run build first; the installed package includes the compiled helper. The migration itself never contacts Blink or restarts Homebridge.

The guarded file converter requires POSIX ownership and file semantics. On Windows, use Homebridge's backup and JSON Config editor to perform the mapping below before starting with legacy keys; already-canonical Windows configurations need no conversion.

Upgrade from 1.1.0 to 2.0.0

The new media backend requires an external FFmpeg 6.1+ installation with the documented capabilities. Install it on the Homebridge host before upgrading. Check that the Homebridge service can find ffmpeg, or set an absolute ffmpegPath through Advanced & troubleshooting. The packaged helper provides libSRTP protection and guarded launch, without FFmpeg codec libraries. Earlier bundled-worker acceptance does not qualify the external executable.

An already-canonical 1.1.0 configuration needs no data conversion for this change. Existing valid ffmpegPath values are preserved. If 1.1.0's previous migration removed a legacy path, choose the external executable explicitly; do not replace the complete configuration with an old backup. Keep authentication, accessory persistence and HomeKit pairing. Restart the Blink child bridge and verify live video/audio plus a fresh retained Home recording after upgrading.

Intermediate beta Early Notification and journal conversion

These settings were introduced after stable 0.10.0. A normal 0.10.0 upgrade has no Early Notification preference or HSV journal to convert. If you used an intermediate 1.1.0 beta, retain its journal and apply the relevant rules below.

At global, Sync Module and camera scopes, disableEarlyNotification: true becomes earlyNotificationMode: "off"; explicit false becomes "unmanaged". An absent override continues to inherit. A valid explicit new mode wins if both keys exist, and the legacy key is removed. Malformed values fail conversion without modifying the supplied file. Unknown fields and other plugins survive. Choosing "on" is a new explicit action; the migration never infers it from an old false value. See Early Notification.

The private .early-notification-ACCOUNT-TIER.json companion journal distinguishes an unverified pending intent from a confirmed owned setting change. The plugin saves a pending original before a new setting POST and promotes it only after the command confirms the requested change. Pending entries never authorize automatic restoration. A refused write whose cleanup cannot persist therefore cannot become an owned change merely because someone later supplies the same value manually. An unchanged read may reconfirm continuity only for a previously confirmed-owned entry when no intervening change was observed; it cannot establish ownership of a new, migrated or otherwise unverified pending entry. A definite Live View, storage or unrelated ordinary-command admission refusal that started no work may retain that same prior ownership, provided no change callback ran and the account/writer scope is still current. Routine contention therefore does not turn a previously owned entry into an unverified change. A typed terminal failure of the initial configuration GET can retain the same prior ownership: that read has ended without reaching the change callback or a setting POST. The SDK checks account/writer authority on failure as well as success; a stale continuation cannot supply that proof. Typed request-local proof that no request was sent is treated similarly. If a reapply read observed the original value, an unsent or refused write cannot own a new change, so its pending intent is discarded. If restoration observed the still-owned forced value, an unsent or refused write can retain that prior ownership. Generic timeouts, uncertain network outcomes and authority changes do not supply this proof and remain pending.

At the first safe account-scoped startup, journal versions 1 and 2 are migrated once to version 3, with an exact-byte private backup beside the journal named JOURNAL.vVERSION-backup-SHA256.json. This is separate from the explicit configuration conversion: that tool cannot identify and validate the active account journal safely. Every legacy original is preserved as pending because those formats do not prove whether its setting write succeeded. Opening settings does not perform this migration. Already-current journals are not rewritten just to load them.

An unresolved pending entry requires manual review before that camera's preference can be managed again. Other cameras, push reception, recording and arm/disarm work remain available. Do not infer ownership from a matching current Blink value. To resolve an entry:

  1. Stop the Blink child bridge and retain a private copy of the current journal and its migration backup.
  2. Identify the entry's camera confidently and choose its intended Early Notification value in the Blink app. The retained original value is evidence for that review, not proof that the plugin changed the setting.
  3. Remove only the reviewed pending entry from the current journal, preserving all other entries and its private file ownership and permissions. Leave any entry you cannot identify pending; never clear the journal wholesale.
  4. Restart the child bridge. An explicitly configured Force on/off policy can then make a new, recorded change. Use Leave unchanged if no forcing is wanted.

An older beta cannot read version 3 or interpret the new mode key. Before a downgrade, resolve pending entries manually, select Leave unchanged for managed cameras and verify confirmed-owned restoration completes. Retain the current journal as well as the pre-upgrade backups. Stop the child bridge before restoring reviewed configuration/journal backups and installing the older exact registry version. Package rollback alone does not convert configuration or operational state; do not discard unresolved originals to make a downgrade start.

Upgrade from 0.10.0

The published 0.10.0 configuration includes retired live-view settings such as ffmpegDebug, rtspTransport, videoEncoder, twoWayAudio and debugStreamPath, plus enableMotionPolling. The combined converter below removes retired media options, maps ffmpegDebug to mediaDebug, maps audioCodec: "aac-eld" to "opus", and converts enableMotionPolling to exposeMotionDetected. Valid explicit canonical values win. The supported ffmpegPath is preserved; verify that it points to an installed FFmpeg meeting the current requirements. Unknown fields, other platforms, credentials and current camera identities are preserved. It does not enable HSV automatically.

The 2.0 series removes optional raw diagnostic file capture. Any existing configuration containing debugStreamPath, including a blank value, requires the explicit preview/--apply conversion below before restart, or manual removal on Windows. Installation never runs this conversion. The converter removes only the setting; it does not scan, move, delete or change permissions on existing capture files. Runtime also leaves those files untouched. Live streaming, HomeKit recording and bounded, redacted mediaDebug logs remain.

  1. Make a private Homebridge backup. Keep existing authentication, accessories and pairing state. Close settings/JSON editors and stop other configuration writers.
  2. Install through normal Homebridge tooling. Installation leaves the saved configuration untouched; an installer storage environment variable does not authorize or run a migration.
  3. Use the explicit preview and --apply procedure below before starting with legacy settings. Use the installed plugin path in place of the checkout-relative scripts/ path.
  4. Restart the Blink child bridge. Open settings and confirm an unchanged editor remains clean. Verify sign-in, existing accessories and controls, then follow the per-camera HSV setup.

Both installed migration script names now use the same combined converter. migrate-secure-media-config.cjs also defaults to preview and requires --apply to write; its historical implicit-write behavior is removed. Running either converter after a successful conversion is a no-op without another backup. Neither contacts Blink, changes the installed version or restarts Homebridge.

Windows manual conversion

Automatic conversion deliberately skips Windows; the file writer requires POSIX ownership semantics. Keep a private Homebridge backup, close competing editors, and use JSON Config to make the conversion below in each BlinkCameras platform. Preserve other plugins and unknown fields. An already-canonical configuration needs no conversion.

  • Preserve ffmpegPath. Remove ffmpegDebug, rtpSsrcMode, rtspTransport, verifyImmisTls, twoWayAudio, videoEncoder and debugStreamPath (even blank). Leave existing capture files untouched. Before removing ffmpegDebug, copy its boolean to mediaDebug if mediaDebug is absent.
  • Map audioCodec: "aac-eld" to "opus". For historical nested audio/video objects, remove audio.aacEldEncoder, audio.twoWay and video.encoder, and map audio.codec: "aac-eld" to "opus".
  • Copy boolean enableMotionPolling to exposeMotionDetected only if the latter is absent, then remove enableMotionPolling.
  • Intermediate beta users must also apply the Early Notification and recording mappings in this guide. Review conflicting camera aliases manually; do not guess identity or discard unresolved journal evidence.

Save the converted configuration, restart the Blink child bridge and verify it. The plugin and settings editor intentionally reject retired keys instead of interpreting them indefinitely at runtime.

Preview and apply native recording settings

Run the converter from this checkout with a supported Node.js version (20.3+, 22, 24 or 26):

node "scripts/migrate-native-recording-config.cjs" "/explicit/path/to/config.json"

The default is a preview. It reads only the supplied complete Homebridge JSON configuration, reports counts and issue codes, and creates no files. It never discovers a Homebridge host, reads authentication files, contacts Blink, uploads data, or restarts a service. Review its output and the relevant configuration locally before applying it:

node "scripts/migrate-native-recording-config.cjs" "/explicit/path/to/config.json" --apply

Use the account that owns the configuration, with write permission in its directory. The converter supports POSIX permissions on macOS and Linux. Close other settings editors and stop concurrent configuration writes during application. It detects identity, metadata, or content changes after inspection and checks again immediately before replacement. An uncooperative writer could still race the final check and rename; the tool does not lock Homebridge's editor.

Before replacement, the converter writes and syncs an exact original-byte backup beside the configuration:

config.json.native-recording-backup-<unique-id>.json

The backup uses mode 0600; the replacement preserves the original config's access permission bits. Both retain the original file's owner and group. The replacement is staged in the same directory and promoted with an atomic rename. Unchanged input creates no backup. Repeating a completed migration leaves the file unchanged. A failure before promotion preserves the original; a completed backup is retained. The error code replaced-directory-sync-failed means replacement happened but its final directory sync failed, so inspect the configuration and retained backup locally.

Conversion rules

Only entries whose platform is BlinkCameras change. Other platforms, bridge settings, credentials, and unknown fields are preserved.

Previous setting New setting
enableMotionPolling boolean exposeMotionDetected, only when the new value is absent; remove the old key
Top-level hksvCameras: string[] Merge homeKitSecureVideo: true into an exactly matching deviceSettingOverrides row, or append a row with that selector; remove hksvCameras
hksvSource Remove the obsolete live-feed/saved-clips source selection; the redesign uses completed USB motion clips
syncModuleRecording Remove obsolete module-specific source and recurring clip-polling overrides

The valid syncModuleFeedLimits setting is preserved. It limits explicit live viewing through the existing secure-media admission owner; it does not schedule native USB clip acquisition.

Explicit new booleans take precedence, including homeKitSecureVideo: false. Existing per-device fields are preserved. Qualified selectors such as camera:123, owl:123, and doorbell:123 retain their kind and ID. Bare IDs, serials, and native Blink names are also retained exactly; HomeKit display-name aliases are not inferred.

The verified previous implementation used top-level hksvCameras. No nested hksv.cameras envelope was established, so an hksv object is preserved and reported as a conflict for manual review rather than guessed.

Conflicts block the entire application, including otherwise valid conversions. They include malformed choices, duplicate selector rows, and a qualified/raw-ID collision that could select or shadow the wrong camera under first-row matching. Fix the conflict in the original configuration, then preview again.

The warning unresolved-camera-aliases requires review: different name/serial/ID selectors may refer to the same camera. This cannot be established from configuration alone. The converter preserves them and does not merge aliases. Review row order because the first matching per-device row applies.

The report lists removed setting names under removedKeys. This includes the native keys in the table above and the retired secure-media keys listed in the Windows conversion checklist. Their original values remain in the private original-byte backup. Other unknown settings are preserved.

Reports contain counts, platform array indexes, and fixed issue codes; they do not print configuration values or selectors. Exit status is 0 for a successful preview/application or no-op, 2 for conversion conflicts or invalid command arguments, and 1 for a file or parsing failure.

Resulting configuration

Motion sensors default to enabled. HSV defaults to disabled for each camera. Leaving a per-device exposeMotionDetected value absent inherits the global choice. HSV still receives motion events when a camera's sensor is hidden.

{
  "platform": "BlinkCameras",
  "name": "Blink",
  "exposeMotionDetected": true,
  "deviceSettingOverrides": [
    {
      "deviceIdentifier": "camera:123",
      "exposeMotionDetected": false,
      "homeKitSecureVideo": true
    }
  ],
  "nativeRecording": {
    "initialDelaySeconds": 60,
    "retryIntervalSeconds": 5,
    "maxRetries": 10
  }
}

The script takes the complete Homebridge document containing platforms, not this individual platform example. Omitted native recording fields use the defaults validated by src/native-recording-config.ts:

Field Default Allowed range
initialDelaySeconds 60 0–3600
retryIntervalSeconds 5 1–300
maxRetries 10 0–100
matchToleranceSeconds 15 0–300
catalogRefreshSeconds 60 60–3600
maxQueuedJobs 128 1–1024
maxJobAgeSeconds 900 1–86400
maxCachedBytes 134217728 33554432–1073741824

All fields are integers. Maximum job age must be greater than the initial delay, leaving a nonempty ordinary acquisition window before expiry. Missing clip retries share completed catalogs and respect the catalog refresh interval; an unknown remote command outcome retains uncertainty within the bounded local lease described in the configuration guide, then permits a distinct action after expiry without replaying the old POST. Restart the Blink child bridge after reviewing and applying configuration. Migration does not grant Apple Home recording permission or arm Blink.

For each recording camera, arm Blink and enable camera motion detection, then confirm a new native Local Storage clip plays in the Blink app. In Apple Home, open the camera tile and Settings → Recording Options. Set When Home and When Away separately to Stream & Allow Recording for the modes where you want recordings. Check the currently active mode; Stream alone does not allow recording. Under More Options, use Any Motion for initial verification, review any Activity Zones, and choose Record Audio if wanted. A connected compatible home hub and an eligible iCloud+ plan are also required. Complete the recording setup checklist and verify a saved clip plays in that camera's Home timeline; motion notifications or live viewing alone do not confirm recording.

To restore the original configuration, retain the current file separately and restore a copy of the selected backup under the original owner and group, with the original config's required access permissions (for example, 0640 when the Homebridge service reads through its group). Keep the backup itself private at 0600. The migration tool does not automatically restore backups or manage services.